Resting ECG Edan SE-601A
From CHF 1'595.00 CHF 1'759.00 Incl. TVA
The Edan SE-601 electrocardiograph is Edan’s 6-channel ECG with a host of features. Space-saving and lightweight, the Edan SE-601 ECG is equipped with a handle for easy transport. This ECG performs recordings in automatic or manual mode with parameter calculation, and its integrated keyboard enables rapid patient data entry. The device automatically detects the presence of a pacemaker.
Description
Brand
Edan
Additional information
Weight | 2.6 kg |
---|---|
Dimensions | 31 × 32.2 × 10.1 cm |
ECG Interpretation | Without interpretation option, Glasgow ECG Analysis |
ECG Heart rate range | 30~300 bpm |
ECG Precision | 1 bpm |
ECG Lead mode | 12 standard leads |
ECG Acquisition mode | 12 leads simultaneously |
ECG A/D resolution | 24 bits |
ECG Resolution | 2.52 uV/LSB |
ECG Time constant | ≥3.2s |
ECG Frequency response | 0.05 Hz~150 Hz (-3 dB) |
ECG Gain | 2.5, 5, 10, 20, 10/5, AGC (mm/mV), ±5% (in mm/mV) |
ECG Input impedance | ≥ 50 MΩ (10Hz) |
ECG Input circuit current | ≤ 0.01μA |
ECG Patient leakage current | NC <10μA (AC) / <10μA (DC) // SFC <50μA (AC) / <50μA (DC) |
ECG Auxiliary patient current | NC <10μA (AC) / <10μA (DC) // SFC <50μA (AC) / <50μA (DC) |
ECG Input voltage range | ±5 mVpp |
ECG Calibration voltage | 1 mV ±2 |
ECG DC offset voltage | ± 600 mV |
ECG Noise | ≤ 12.5 μl Vp-p |
ECG Filters | AC filter: On/Off // DFT filter: 0.05 Hz / 0.15 Hz / 0.25 Hz / 0.32 Hz / 0.5 Hz / 0.67 Hz // EMG filter: 25 Hz / 35 Hz / 45 Hz / Off // LOW-PASS filter: 150 Hz / 100 Hz / 75 Hz |
ECG Sampling frequency | 1,000 Hz / bypass |
ECG Amplitude Pacer | ± 2 to ± 700 mV |
ECG Pacer Width | 0.1 to 2.0 ms |
ECG Pacer Sampling frequency | 10,000 Hz / rhythm derivation |
Screen | SE-601A: 3.5" single-color LCD // Models SE-601B (5.6/5.7" multi-color TFT LCD) and SE-601C (5.6/5.7" multi-color TFT touchscreen LCD) are available on request. |
Printer | Thermal matrix printer // Paper: 110×140 mm 150 pages (actual width 104 mm) // Speed: 5, 6.25, 10, 12.5, 25, 50 mm/s (±3%) |
Use | Temperature: +5 ºC ~ +40 ºC // Atmospheric pressure: 860hPa ~1060hPa |
Storage | Temperature: -20 ºC ~ +55 ºC // Atmospheric pressure: 700hPa ~1060hPa |
Humidity | Operating temperature: 25%~80% non-condensing // Storage temperature: 25%~93% non-condensing |
Power supply | 100-240 V~ 50 Hz/60 Hz 0.9 A-0.4 A // 2500 mAh lithium-ion battery pack |
Autonomy | With charged battery: Operate for up to 5 hours and print for 1.5 hours in MANU mode or print 300 3×4+1R ECG reports in AUTO mode |
Refill | 100% charge time: 5 hours // 90% charge time: 4.5 hours |
Classification | Protection against electric shock Class I // RF emissions CISPR 11 Group 1 Class A |
Certification | CEI 60601-1:2005/A1:2012 // EN 60601-1:2006/A1:2013 // CEI 60601-1-2:2014 // EN 60601-1-2:2015 // CEI/EN 60601-2-25 |
Compliance | Complies with European Committee 93/42/EEC recommendations on medical devices |
Warranty | 2 years, excluding cables and accessories |