Edan SE-301 – Compact 3-channel digital electrocardiograph with touch screen
From CHF 1,655.00 CHF 1,947.00 Incl. TVA
The Edan SE-301 is a portable 3-channel electrocardiograph with a 5″ touch screen. Battery-powered, it offers over 3 hours of autonomy. The device can record and export ECG traces in digital format. CE-certified model, compatible with Edan ECG accessories.
Description
Brand
Edan
Additional information
| Weight | 1 kg |
|---|---|
| Dimensions | 22.4 × 14.3 × 5.4 cm |
| ECG Interpretation | Without interpretation option, Glasgow ECG Analysis |
| ECG Heart rate range | 30~300 bpm |
| ECG Precision | 1 bpm |
| ECG Lead mode | 12 standard leads |
| ECG Acquisition mode | 12 leads simultaneously |
| ECG A/D resolution | 24 bits |
| ECG Resolution | 0.1575 μV/LSB |
| ECG Time constant | ≥ 3,2 s |
| ECG Frequency response | 0.01Hz ~ 300Hz (-3dB) |
| ECG Gain | 2.5, 5, 10, 20, 10/5, AGC (mm/mV) |
| ECG Input impedance | ≥ 50 MΩ (10Hz) |
| ECG Input circuit current | ≤ 0.01μA |
| ECG Patient leakage current | NC <10μA (AC) / <10μA (DC) // SFC <50μA (AC) / <50μA (DC) |
| ECG Auxiliary patient current | NC <10μA (AC) / <10μA (DC) // SFC <50μA (AC) / <50μA (DC) |
| ECG Input voltage range | ≤ ±5 mVpp |
| ECG Calibration voltage | 1 mV ±3 |
| ECG DC offset voltage | ±600mV |
| ECG Sampling frequency | 16,000 Hz |
| ECG Noise | ≤12,5μVp-p |
| ECG Filters | AC filter: On/Off// DFT filter: 0.05Hz/0.15Hz/0.25Hz/0.32Hz/0.5Hz/0.67Hz //EMG filter: 25Hz/35Hz/45Hz/Off // Low-pass filter: 150Hz/100Hz/75Hz |
| ECG Amplitude Pacer | ±2mV ~ ±700mV |
| ECG Pacer Width | 0.1ms ~ 2.0ms |
| ECG Pacer Sampling frequency | 16,000/s/channel |
| Screen | 800 × 480 LCD |
| Printer | Thermal matrix printer // Folded thermal paper: 80×70 mm 200 pages // Thermal paper roll: 80×20 mm // Speed: 5, 6.25, 10, 12.5, 25, 50 mm/s (±3%) // Accuracy: ±5% (x-axis), ±5% (y-axis) |
| Wi-Fi | Without Wi-Fi module, With Wi-Fi module |
| Use | Temperature: +5 ºC ~ +40 ºC // Atmospheric pressure: 700hPa ~1060hPa |
| Storage | Temperature: -20 ºC ~ +55 ºC // Atmospheric pressure: 700hPa ~1060hPa |
| Humidity | Operating temperature: 15%~95% non-condensing // Storage temperature: 15%~95% non-condensing |
| Power supply | 100 V-240 V~ 50 Hz / 60 Hz 19 V, 2 A |
| Autonomy | With charged battery: Operates for up to 8.5 hours and records for 5 hours in MANUAL mode or records 500 ECG reports in AUTO mode |
| Refill | Charging time required: ≤ 3.5 hours // Life cycle ≥ 300 times |
| Classification | RF emissions CISPR 11 Group 1, Class A |
| Certification | IEC 60601-1:2005/A1:2012 // EN 60601-1:2006/A1:2013 // IEC 60601-1-2:2007 // EN 60601-1-2:2007/AC:2010 // |
| Compliance | Complies with European Committee 93/42/EEC recommendations on medical devices |
| Warranty | 2 years, excluding cables and accessories |