Edan SE-601A – 6-channel digital electrocardiograph with thermal printing
From CHF 1,595.00 CHF 1,759.00 Incl. TVA
The Edan SE-601A is a 6-channel digital electrocardiograph with LCD display and USB port for data management. It can record and print on thermal paper. Compact, CE-certified model, compatible with Edan ECG accessories.
Description
Brand
Edan
Additional information
| Weight | 2.6 kg |
|---|---|
| Dimensions | 31 × 32.2 × 10.1 cm |
| ECG Interpretation | Without interpretation option, Glasgow ECG Analysis |
| ECG Heart rate range | 30~300 bpm |
| ECG Precision | 1 bpm |
| ECG Lead mode | 12 standard leads |
| ECG Acquisition mode | 12 leads simultaneously |
| ECG A/D resolution | 24 bits |
| ECG Resolution | 2.52 uV/LSB |
| ECG Time constant | ≥3.2s |
| ECG Frequency response | 0.05 Hz~150 Hz (-3 dB) |
| ECG Gain | 2.5, 5, 10, 20, 10/5, AGC (mm/mV), ±5% (in mm/mV) |
| ECG Input impedance | ≥ 50 MΩ (10Hz) |
| ECG Input circuit current | ≤ 0.01μA |
| ECG Patient leakage current | NC <10μA (AC) / <10μA (DC) // SFC <50μA (AC) / <50μA (DC) |
| ECG Auxiliary patient current | NC <10μA (AC) / <10μA (DC) // SFC <50μA (AC) / <50μA (DC) |
| ECG Input voltage range | ±5 mVpp |
| ECG Calibration voltage | 1 mV ±2 |
| ECG DC offset voltage | ± 600 mV |
| ECG Noise | ≤ 12.5 μl Vp-p |
| ECG Filters | AC filter: On/Off // DFT filter: 0.05 Hz / 0.15 Hz / 0.25 Hz / 0.32 Hz / 0.5 Hz / 0.67 Hz // EMG filter: 25 Hz / 35 Hz / 45 Hz / Off // LOW-PASS filter: 150 Hz / 100 Hz / 75 Hz |
| ECG Sampling frequency | 1,000 Hz / bypass |
| ECG Amplitude Pacer | ± 2 to ± 700 mV |
| ECG Pacer Width | 0.1 to 2.0 ms |
| ECG Pacer Sampling frequency | 10,000 Hz / rhythm derivation |
| Screen | SE-601A: 3.5" single-color LCD // Models SE-601B (5.6/5.7" multi-color TFT LCD) and SE-601C (5.6/5.7" multi-color TFT touchscreen LCD) are available on request. |
| Printer | Thermal matrix printer // Paper: 110×140 mm 150 pages (actual width 104 mm) // Speed: 5, 6.25, 10, 12.5, 25, 50 mm/s (±3%) |
| Use | Temperature: +5 ºC ~ +40 ºC // Atmospheric pressure: 860hPa ~1060hPa |
| Storage | Temperature: -20 ºC ~ +55 ºC // Atmospheric pressure: 700hPa ~1060hPa |
| Humidity | Operating temperature: 25%~80% non-condensing // Storage temperature: 25%~93% non-condensing |
| Power supply | 100-240 V~ 50 Hz/60 Hz 0.9 A-0.4 A // 2500 mAh lithium-ion battery pack |
| Autonomy | With charged battery: Operate for up to 5 hours and print for 1.5 hours in MANU mode or print 300 3×4+1R ECG reports in AUTO mode |
| Refill | 100% charge time: 5 hours // 90% charge time: 4.5 hours |
| Classification | Protection against electric shock Class I // RF emissions CISPR 11 Group 1 Class A |
| Certification | CEI 60601-1:2005/A1:2012 // EN 60601-1:2006/A1:2013 // CEI 60601-1-2:2014 // EN 60601-1-2:2015 // CEI/EN 60601-2-25 |
| Compliance | Complies with European Committee 93/42/EEC recommendations on medical devices |
| Warranty | 2 years, excluding cables and accessories |