Edan F2 twin fetal monitor
CHF 2,799.00CHF 3,236.00
The Edan F2 is a twin fetal monitor, also known as a cardiotocograph. It is equipped with 2 RCF channels and one external TOCO channel. This robust, lightweight device weighs just 3.5 kg, making it easy to transport for home consultations. The Edan F2’s IPX8 waterproof sensors have a very high sensitivity (optimum frequency of 1 MHz) for better wave penetration and protection of foetal tissue. Fetal movement detection can be automatic or manual. CTV calculation: This program is used for monitoring intrauterine growth retardation (IUGR). It analyzes fetal heart rate and calculates short-term variability. This option is integrated into the F2 cardiotocograph. The rechargeable battery has no memory effect, allowing the Edan F2 to be used while charging. Monitoring F2 also works directly from the mains.
Description
Brand
Edan
Additional information
Weight | 3.5 kg |
---|---|
Dimensions | 35 × 30 × 10.4 cm |
Type | Heart rate analysis with calculation of STV (Short-Term Variability), including SOV technology for twin pregnancies |
Screen | 5.6" black and white // RGB resolution 640 x 480 // Plot and number display |
Keyboard | Silicone keypad for easy monitoring |
Indicators | Signal quality indicator helps optimize sensor position |
Ultrasound - Technology | Ultrasonic Doppler with auto-correction |
Ultrasonic - Repetition rate | 2 KHz |
Ultrasonic - Pulsation | Duration: 92 μs |
Ultrasonic - Frequency | 1 MHz ±10 |
Ultrasonic - Measuring range | 50 bpm-240 bpm |
Ultrasonic - Resolution | 1 bpm |
Ultrasonic - Precision | ± 2 bpm |
Toco - Measuring range | 0%-100% |
Toco - Resolution | 1% |
Toco - Zeroing | Automatic / Manual |
Toco - Non-linear error | 10% |
Fetal ECG - Technology | Peak-to-peak detection |
Fetal ECG - Measuring range | 30 bpm-240 bpm |
Fetal ECG - Resolution | 1 bpm |
Fetal ECG - Accuracy | ± 1 bpm |
Fetal ECG - CMRR | >110 dB |
Fetal ECG - Noise | < μVP |
Fetal ECG - Impedance | >10 M (differential, DC 50/60 Hz) // >20 M (common mode) |
PlU - Intrauterine pressure - Measuring range | 0mmHg-100mmHg |
PlU - Intrauterine pressure - Resolution | 1% |
PlU - Intrauterine pressure - Zeroing | Automatic – Manual |
PlU - Intrauterine pressure - Non-linear error | ±3 mmHg |
Automatic Fetal Movement - Technology | Ultrasound Doppler |
Automatic Fetal Movement - Measuring range | 0%-100% |
Automatic Fetal Movement - Resolution | 1% |
Manual Fetal Movement - Method | Remote marker |
Registration - Type | Thermal printer |
Registration - Paper | Thermo-sensitive paper (150mm) |
Recording - Speed | 1/2/3 cm/min (in real time) |
Registration - Resolution | 8 dots/mm |
Registration - Information | RCF1 trace, RCF2 trace, TOCO trace, MFA trace, fetal movement mark, event mark, aut-zero symbol, date, time, recording speed, ID, name, RCF2 offset, etc. |
Power supply | 100 V- 240 V |
Refill | Rechargeable 14.8 V Lithium battery for up to 7 hours of autonomy |
Power | Battery capacity: 4200 mAh/2100 mAh |
Warranty | 3 years, cables and accessories 1 year |