Resting ECG Edan SE-1201
From CHF 2'346.00 Incl. TVA
Discover the Edan SE-1201 12-channel electrocardiograph, compact and lightweight, easy to carry thanks to its integrated handle. The Edan SE-1201 ECG enables recordings to be made in automatic or manual mode, including Glasgow measurements and interpretations, as well as arrhythmia detection. It displays all 12 leads on its large color LCD touchscreen. Simple and intuitive, the user can quickly enter the patient’s gender and age range using specific buttons on the alphanumeric keypad. This ECG features a wide range of functions and great connectivity, allowing you to transfer your reports (A4 format, 12-lead ECG) directly as PDF files to a USB key. It incorporates a high-resolution thermal printer for comfortable, scalable plotting in A4 format. Rechargeable Li-Ion battery for a range of around 300 tests.
Description
Brand
Edan
Additional information
Weight | 5 kg |
---|---|
Dimensions | 36.1 × 26.2 × 13.5 cm |
ECG Heart rate range | 30~300 bpm |
ECG Precision | 1 bpm |
ECG Lead mode | 12 standard leads |
ECG Acquisition mode | 12 leads simultaneously |
ECG A/D resolution | 24 bits |
ECG Time constant | ≥3.2s (0, +20%) |
ECG Frequency response | 0.05 Hz~150 Hz (-3 dB) |
ECG Gain | 2.5, 5, 10, 20, 10/5, AGC (mm/mV) |
ECG Input impedance | ≥ 50 MΩ (10Hz) |
ECG Input circuit current | ≤ 0.01μA |
ECG Patient leakage current | NC <10μA (AC) / <10μA (DC) // SFC <50μA (AC) / <50μA (DC) |
ECG Auxiliary patient current | NC <10μA (AC) / <10μA (DC) // SFC <50μA (AC) / <50μA (DC) |
ECG Input voltage range | ≤ ±5 mVpp |
ECG Calibration voltage | 1 mV ±2 |
ECG DC offset voltage | ±600mV |
ECG Sampling frequency | 1000 Hz |
ECG Signal Amplification | CMRR (Common Mode Rejection Ratio) : ≥ 115 dB |
ECG Noise | ≤12.5 μVp-p |
ECG Filters | AC filter: On/off // DFT filter: 0.05Hz/0.15Hz/0.25Hz/0.32Hz/0.5Hz/0.67Hz // EMG filter: 25Hz/35Hz/45Hz/OFF // Low-pass filter: 150Hz/100Hz/75Hz |
ECG Amplitude Pacer | ±2 to ±700 mV |
ECG Pacer Width | 0.1 to 2.0 ms |
ECG Pacer Sampling frequency | 10,000/s/channel |
Screen | Without touchscreen, With touch screen |
Printer | Thermal matrix printer // Paper: 210×140, 216×140, 210×295, 215×280 mm // Speed: 5, 6.25, 10, 12.5, 25, 50 mm/s (±3%) // Accuracy: ±5% (x-axis), ±5% (y-axis) |
Wi-Fi | Without Wi-Fi module, With Wi-Fi module |
Use | Temperature: +5 ºC ~ +40 ºC // Atmospheric pressure: 860hPa ~1060hPa |
Storage | Temperature: -20 ºC ~ +55 ºC // Atmospheric pressure: 700hPa ~1060hPa |
Humidity | Operating temperature: 25%~80% non-condensing // Storage temperature: 25%~93% non-condensing |
Power supply | 100V~240V 50/60Hz 0.9-0.4A // Integrated 14.8V 2200mAh lithium battery pack |
Autonomy | With charged battery: Operate for up to 4 hours and print for 1.5 hours in MANU mode or print 300 3×4+1R ECG reports in AUTO mode |
Refill | Mode: voltage / direct current // Current (standard): 0.45 C5 A (1000mA) // Voltage (standard): 16.8V // Final discharge voltage: 12V // Charging time: 3 hours // Service life ≥ 300 times |
Classification | Protection against electric shock Class I // RF emissions CISPR 11 Group 1 Class A |
Certification | IEC/EN 60601-1+A1+A2, IEC/EN60601-1-2+A1 // IEC/EN60601-2-25, ANSI/AAMI EC11 // IEC/EN 60601-2-51 |
Compliance | Complies with European Committee 93/42/EEC recommendations on medical devices |
Warranty | 2 years, excluding cables and accessories |